2.2kW 240V single-phase, 12L cast iron tank, 20MPa (2,900 PSI), G3/8 port, vertical mount. Fits most Australian 2 and 4-post workshop hoists. Shipped from Melbourne within 24 hours.
Will This Fit Your Hoist? Check 4 Points
| Check | This Unit | If Different |
|---|---|---|
| Power supply | Single phase 240V — 15-amp circuit | Need 3-phase? See our 3-phase 12L unit |
| Port size | G3/8 (approx. 17mm BSP thread) | Measure your existing fitting before ordering |
| Mounting orientation | Vertical only — motor shaft faces up | Horizontal cast iron variant available separately |
| Max system pressure | 20MPa / 2,900 PSI | If your hoist requires >20MPa this unit is not suitable |
Covers most Australian 2-post hoists to 4 tonne and 4-post hoists to 5 tonne. Check the hoist nameplate if unsure of rated pressure.
Cast Iron vs Aluminium Pump Body
| Cast Iron (this listing) | Aluminium Body | |
|---|---|---|
| Best for | Workshops — 10+ lift cycles per day | Home garage or low-volume use — 5 or fewer cycles/day |
| Heat under load | Runs cooler — greater thermal mass | Heats faster under back-to-back cycles |
| Weight | 25 kg {{VERIFY: weight | spec sheet}} | Lighter |
| Service life | Longer at high cycle rates | Adequate for occasional use |
If you are unsure, choose cast iron. The price difference is small; the durability advantage in a working shop is significant.
6L vs 12L Tank — What the Difference Means in Practice
| 6L Tank | 12L Tank (this unit) | |
|---|---|---|
| Typical use | Home garage, panel shop | Service workshop, tyre shop, mechanical |
| Cars per day | Up to 5 | 8 or more |
| Oil temperature under sustained use | Rises faster — accelerates oil and pump wear | Stays lower — more thermal buffer per cycle {{VERIFY: temperature differential | hydraulic service technician field data}} |
| Verdict | Cost-reduction compromise | Correct specification for commercial throughput |
What's Included — Components and Failure Signs
| Component | Function | If It Fails |
|---|---|---|
| Suction filter | Keeps debris out of pump intake | Slow or weak lift — check this first. Clean or replace annually. |
| Return oil pipe | Returns oil from cylinder to tank | Visible oil leak at return connection |
| Air breather | Pressure equalisation in reservoir | Cavitation noise, pump starves of oil — do not block or remove |
| Relief valve | Limits system to 20MPa — factory set | Hoist won't reach full lift height; unit runs but pressure is low |
| Check valve | Holds lift at height — prevents backflow | Hoist slowly drops after reaching height |
Wiring Requirements
Minimum: dedicated 15-amp single-phase 240V circuit. Full-load draw approximately 10–12 amps. {{VERIFY: amp draw | motor nameplate}}
Do not run from a 10-amp GPO or extension cord. Cold-start inrush on a dual-capacitor motor can trip a 10-amp breaker. Install the circuit outlet within 1.5 metres of the hoist.
Common Questions
Will this fit my hoist brand?It fits most Australian commercial workshop hoists using single-phase 240V and a G3/8 port — the standard fitting on the vast majority of hoists sold in Australia. Confirm port size and mounting orientation. If the hoist was installed by a licenced mechanic into a standard workshop, it is almost certainly a direct swap.
Motor runs but hoist lifts slowly — pump failure?Check oil level first — free fix. If level is correct, inspect the suction filter for partial blockage. If both are fine, the pump is worn. Replacement is more cost-effective than internal pump repair.
What hydraulic oil and how much?AW46 (ISO VG 46 Anti-Wear) hydraulic oil. Fill to the MAX line on the sight glass with the hoist fully lowered — approximately 8–10 litres. {{VERIFY: fill volume | check in-hand}} Always use fresh oil when fitting a new power unit; old contaminated oil shortens pump life.
What is 20MPa in PSI?20MPa = 2,900 PSI (1 MPa = 145 PSI). This covers most Australian commercial hoists rated to 4–5 tonne. The relief valve is factory-set to this limit. Check your hoist nameplate for rated working pressure if unsure.
Warranty and contact?12 months from date of purchase. Contact HankeMotor at hankemotors@gmail.com or call 0401 634 280, Mon–Fri 9:00am–5:30pm.